La protección de distancia y las condiciones de prefalla/The distance protection and the pre-fault conditions
| Dublin Core | Elementos de metadatos PKP | Metadatos para el documento | |
| 1. | Título | Título del documento | La protección de distancia y las condiciones de prefalla/The distance protection and the pre-fault conditions |
| 2. | Creador/a | Nombre de autor/a, institución, país | Osmel Pérez Baluja; Universidad Tecnológica de La Habana; Cuba |
| 2. | Creador/a | Nombre de autor/a, institución, país | Orlys Ernesto Torres Breffe; Universidad Tecnológica de La Habana; Cuba |
| 2. | Creador/a | Nombre de autor/a, institución, país | Lenyer Padrón; Empresa Eléctrica de La Habana; Cuba |
| 3. | Materia | Disciplina(s) | Trabajo Teóricoexperimental |
| 3. | Materia | Palabra/s clave | Protección de distancia; condiciones de Prefalla; Cortocircuito; Resistencia de falla; Distance Protection; Pre-Fault; Short circuit. |
| 4. | Descripción | Resumen | En la actualidad en los Sistema Eléctricos de Potencia, en ocasiones se continua utilizando la función de distancia (21) como protección principal en líneas de transmisión lo que no es correcto ya que la protección de distancia se ve afectada por múltiples fenómenos, dígase oscilaciones de potencia, efecto de la inducción mutua entre líneas, condiciones de prefalla, que pueden llevar a una incorrecta operación de la protección, así como también la incapacidad de disparo simultáneo en In the present time in the Electric System of Power, in occasions you continuous using the distance function (21) as main protection in transmission lines what is not correct since the distance protection is affected by multiple phenomena, say you oscillations of power, effect of the mutual induction among lines, pre-fault conditions that can take to an incorrect operation of the protection, as well as the inability of simultaneous shot in both ends of the line that it protects. In this work the results of the mathematical analysis of a system are presented with lines of 110 kw where the phenomena and difficulties are evidenced that introduce to the distance protection taking alone in bill the negative effect of the flaw resistance and the conditions that existed before the flaw, as well as their possible solutions which are not completely effective. |
| 5. | Editorial | Institución organizadora, ubicación | Universidad Tecnológica de La Habana "José Antonio Echeverría" (Cujae) |
| 6. | Colaborador/a | Patrocinador(es) | |
| 7. | Fecha | (DD-MM-AAAA) | 2019-04-04 |
| 8. | Tipo | Estado y género | Artículo revisado por pares |
| 8. | Tipo | Tipo | |
| 9. | Formato | Formato de archivo | |
| 10. | Identificador | Identificador uniforme de recursos | http://rie.cujae.edu.cu/index.php/RIE/article/view/560 |
| 11. | Fuente | Título; vol., núm. (año) | Ingeniería Energética; Vol. 40, Núm. 2 (2019): Ingeniería Energética |
| 12. | Idioma | Español=es | es |
| 13. | Relación | Archivos complementarios | |
| 14. | Cobertura | Localización geoespacial, periodo cronológico, muestra de investigación (sexo, edad, etc.) | |
| 15. | Derechos | Derechos de autor/a y permisos |
Copyright (c) 2019 Ingeniería Energética |